Generator Diode Bridge and Rectifier RSK6001 70A

Product Details
Brand ZOZHI
Serial Number RSK6001
Country of Origin Fujian China
Certificate ISO, CE
Payment & Shipping Terms
Minimum Order 1pcs
Average Delivery Time 1days
Payment Method TT, western union
Ability to Supply 20000pcs per month

Generator Diode Bridge and Rectifier RSK6001 70A 

  • Model: RSK6001 Set
  • Origin: China
  • Warranty: 1 Year
  • In stock: Yes
  • Product description: The 70A diodes on the main Stamford RSK6001 Bridge Rectifier assembly can be checked with a multimeter.

Stamford Diode Rectifier RSK6001 is responsible for providing power to the Alternator rotor so it can induce voltage to the main winding of a Stamford alternator. 

The Stamford Generator Bridge Rectifier RSK6001 is suitable for Stamford Alternators HC634, HC644, HC734, HC744 and Frame 8 series.

RSK6001 Stamford Generator Bridge Rectifier includes:
Positive Diodes * 3
Negative Diodes * 3
Surge Suppressor (Varistor) * 2


The diodes on the main Stamford RSK6001 Bridge Rectifier assembly can be checked with a multimeter. The flexible leads connected to each diode should be disconnected at the terminal end, and the forward and reverse resistance checked. (See section 2, diode testing).  The rectifier assembly is split into two plates, positive and negative, and the main rotor is connected across these plates.  Each plate carries 3 diodes, the negative plate carries the negative based diodes, and the positive plate carries the positive based diodes.  Care must be taken to ensure that three identical polarity diodes are fitted to each plate. When fitting the diodes to the plates they must be tight enough to ensure a good mechanical and electrical contact, but should not be over tightened.  The recommended torque tightening is 4.06 to 4.74 Nm, (14 to 17 kg/cm).

 
The Surge Suppressor (Varistor) in the RSK6001 Stamford Bridge Rectifier, is a protection device, which prevents high voltage transients from damaging the main rectifier diodes.  High Voltage transients are created by fault conditions in the distribution system. The Voltage transient returns back to the Generator output terminals enter the main stator windings, and by mutual inductance, is transferred to the main rotor windings, and the main rectifier assembly.

The Surge Suppressor of Stamford RSK6001 Bridge Rectifier can be tested with a Multimeter on the Megohms range.  A good Surge Suppressor should have very high resistance, (more than 100 Megohms in either direction).  A faulty Surge Suppressor will be either open circuit (usually showing signs of burning) or short circuit in both directions.  

The Main Rectifier in the Stamford RSK6001 Diode Bridge will work normally with this device removed.  However, it should be replaced as soon as possible, to avoid diode failure in the event of further transient fault conditions.   Occasionally, a very high transient may totally destroy the Surge Suppressor. This would result from extreme fault conditions, such as lightning, (electric storms), close to overhead distribution lines, or out of phase synchronization of the Generator, when paralleled to multiple Generator systems, (or the Mains, Utility, supply). 

 

Generator Diode Bridge and Rectifier RSK6001

Generator Diode Bridge and Rectifier RSK6001

Generator Diode Bridge and Rectifier RSK6001

Generator Diode Bridge and Rectifier RSK6001

 

FAQ

Q1. What are your terms of packing?
A: Generally, we pack our goods in neutral white boxes and brown cartons. If you have legally registered patent, 
we can pack the goods in your branded boxes after getting your authorization letters.

Q2. What are your terms of payment?
A: T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages 
before you pay the balance.

Q3. What are your terms of delivery?
A: EXW, FOB, CFR, CIF, DDU.

Q4. How about your delivery time?
A: Generally, it will take 30 to 60 days after receiving your advance payment. The specific delivery time depends 
on the items and the quantity of your order.

Q5. Can you produce according to the samples?
A: Yes, we can produce by your samples or technical drawings. We can build the molds and fixtures.

Q6. What is your sample policy?
A: We can supply the sample if we have ready parts in stock, but the customers have to pay the sample cost and 
the courier cost.

Q7. Do you test all your goods before delivery?
A: Yes, we have a 100% test before delivery

Q8: How do you make our business long-term and a good relationship?
A:1. We keep good quality and competitive price to ensure our customers benefit ;
2. We respect every customer as our friend and we sincerely do business and make friends with them, 
no matter where they come from.

 

Generator Diode Bridge and Rectifier RSK6001

Get in Touch with us

Fill out more information, We will get back to you within 24 hours.

Factory Address

NO.155 SHANGCUN QINXIYANG INDUSTRY ZONE,FUAN CITY,FUJIAN,CHINA

Brand

ZOZHI

Contact Us

Business Phone : 0593-6532656

Work Time :08:00-18:00(Beijing time)

contact us